Varla P Setting

  1. Power on your scooter.
  2. Hold the Mode + Power buttons (3seconds) to access the P-setting menu.
  3. Press the Mode button to toggle through P-settings.
  4. Long press the Power button to change the direction of value addition and subtraction, the left display "A" means increasing the value, and the left display "d" means decreasing the value.

 

lcd-display-of-varla-scooter
  1. After adjustment, short press the Power button to switch to the next feature and save the previous feature value.
  2. Press the Power button to select the P-setting to adjust.
  3. To save settings, allow the LCD display to timeout (8seconds) or long press Mode + Power buttons to exit the menu.

 

P-SETTING SPECIFICATION:

Setting

Feature

Notes

P1

LCD brightness

1: low

2: mid

3: high

Default: 3

P2

Speedometer units

0: kph
1: mph
Default: 0

P3

Battery voltage (do not adjust)

From 24V to 60V
Default: 52V

P4

Auto-off time

0: not set
60: 60 min
Default: 5

P5

Unused

 

P6

Wheel diameter (do not adjust)

Default: 10.0

P7

Motor magnets (do not adjust)

From 0 to 255

Default: 28

P8

Power level

1: slowest
100: fastest
Default: 100 km/h

P9

Start mode

0: zero start
1: kick to start
Default: 0

P10

Unused

 

P11

Regenerative/Electronic brake strength

0: off,

1: weak
5: max
Default: 3

P12

Acceleration

0: off

1: weak
5: strong
Default: 3

P13

Unused

 

P14

Unused

 

P15

Automatic scooter voltage shut-down (do not adjust)

From 37.0 to 47.0

Default: 42.0

P16

Lifetime odometer reset

Long-press Mode button to reset to 0

P17

Cruise control

0: off
1: on
Default: 0

P18

Unused

 

P19

Unused

 

P20

Communication protocol (can not adjust)

Default: 4